Teklif sepetiniz boş
Ürün sayfalarından teklif almak istediğiniz ürünleri ekleyin
AE
AEG 24SPRE50
Tiristör kontrollü endüstriyel doğrultucu ve pil şarjDC UPS Protect RCS 24V / 50A
System configuration
System setup Single Operation
Battery configuration Individual battery
The Protect RCS DC UPS System is a microprocessor based thyristor controlled rectifier. It provides high quality DC power for electronic equipment loads.
Mechanical specification
Enclosure free standing metal suitable for floor mounting type V2000 cabinet
Metal sheet thickness Frame 2 mm
Panels 1.5 mm
Door 2 mm
Protection class (according to IEC 60529) IP21
Painting RAL7035
Ventilation Air inlet in the front doors, front and back cabinet bottom, outlet through rear panel on the top
Acoustic noise <66 dB(A)
Cable entry from Bottom
Dimensions:
Height 1200 mm
Width 600 mm
Depth 800 mm
Weight approx. 160 kg
Electrical specification
Rectifier type: 2 pulse (SCR) thyristor
Nominal input voltage 230 VAC
Input voltage tolerance ±10%
Exceptional variation of the mains input voltage +15%, 20%
Number of phases 1
Input frequency 50 Hz
Input frequency tolerance ±6%
Max. input current (10% mains, in high rate charge and Inom on the output) 13 A AC
Rectifier input current total harmonic distortion (THDi) < 66%
Input power at nominal voltage and float charge 0,64
Nominal DC output voltage 24V DC
Nominal DC output current 50A DC
Voltage regulation
Static: ±1%
• at float charge
• 0 100% DC load variation
• input mains voltage within the range ±10%
• input frequency within the range ±6%
• battery temperature within 0°C to 40°C
Dynamic:
With single LC filter with a battery connected
(capacity >5 x nominal current of the rectifier
• load variation 10% => 90% : 5%
• load variation 90% => 10% : +8%
Current regulation +2% at the maximum current level
Ripple voltage:
Ripple voltage with standard battery capacity of 3x nominal current: without batteries 2.5% RMS typically (max 5%) with batteries 1% RMS
Heat losses at rated power 393 W
Long term stability for 1000 hours (of output voltage) 0.15%
Charger characteristic per IEC 47810: IU
High voltage insulation between input/output and electrical earth 2500V AC
(With disconnected electronic boards in the rectifier).
Insulation resistance with disconnected electronic boards in the
Rectifier >200MΩ
Input to ground 500V DC
Input to output 500V DC
Output to ground 500V DC
Protection:
• Slow start function
• Short circuits
• Limited at 100% of rated current
• Internal DC fuse
• Nonvolatile storage of system parameters and user settings
• Mains failure shutdown, Rectifier failure shutdown
• High voltage DC shutdown
• History function for time stamped alarm and system events
Battery adjustments
(If battery is included in scope of supply, it must appear as a separate line in the quote)
Manufacturer Enersys
Type HX
Capacity 47 Ah
Number of cells 0
Number of strings 1
Float charge voltage 0,00 V
High rate voltage 0,00 V
High rate charge time (range 0150h): 4 h
High rate charge timer mode settings Post
Commissioning voltage 0,00 V
End of discharge voltage 0,00 V
Measurements – Alarms
Measurements available on LCD display:
• AC input voltage
• DC charger voltage
• DC charger current
• DC battery current
• Battery capacity
• DC load voltage
• DC load current
Alarm indications:
• Mains voltage alarm
• Charge fault alarm
• Battery voltage alarm
• DC voltage alarm
• Ground fault +/alarm
• Charger current limit alarm
• Battery current limit alarm
• High charger current alarm
• High battery current alarm
• high temperature alarm
• Temperature sensor error alarm
• Internal communication error alarm
• Battery test alarm
• High battery temperature alarm
• Long charge time alarm
• No power supply voltage alarm
• Battery in operation alarm
• Service alarms
List of installed items
• EMI filter (CE)
• Voltage temperature compensation (cable length 30m)
• Bridge temperature alarm
• AC input protection: Switch
• Battery protection: Fuse
• Load protection: None
• Ground fault (by With GCAU)
• Cabinet colour: RAL7035
• Cabinet protection degree: IP21
ORİJİNAL
Tiristör kontrollü endüstriyel doğrultucu ve pil şarjDC UPS Protect RCS 24V / 50A
System configuration
System setup Single Operation
Battery configuration Individual battery
The Protect RCS DC UPS System is a microprocessor based thyristor controlled rectifier. It provides high quality DC power for electronic equipment loads.
Mechanical specification
Enclosure free standing metal suitable for floor mounting type V2000 cabinet
Metal sheet thickness Frame 2 mm
Panels 1.5 mm
Door 2 mm
Protection class (according to IEC 60529) IP21
Painting RAL7035
Ventilation Air inlet in the front doors, front and back cabinet bottom, outlet through rear panel on the top
Acoustic noise <66 dB(A)
Cable entry from Bottom
Dimensions:
Height 1200 mm
Width 600 mm
Depth 800 mm
Weight approx. 160 kg
Electrical specification
Rectifier type: 2 pulse (SCR) thyristor
Nominal input voltage 230 VAC
Input voltage tolerance ±10%
Exceptional variation of the mains input voltage +15%, 20%
Number of phases 1
Input frequency 50 Hz
Input frequency tolerance ±6%
Max. input current (10% mains, in high rate charge and Inom on the output) 13 A AC
Rectifier input current total harmonic distortion (THDi) < 66%
Input power at nominal voltage and float charge 0,64
Nominal DC output voltage 24V DC
Nominal DC output current 50A DC
Voltage regulation
Static: ±1%
• at float charge
• 0 100% DC load variation
• input mains voltage within the range ±10%
• input frequency within the range ±6%
• battery temperature within 0°C to 40°C
Dynamic:
With single LC filter with a battery connected
(capacity >5 x nominal current of the rectifier
• load variation 10% => 90% : 5%
• load variation 90% => 10% : +8%
Current regulation +2% at the maximum current level
Ripple voltage:
Ripple voltage with standard battery capacity of 3x nominal current: without batteries 2.5% RMS typically (max 5%) with batteries 1% RMS
Heat losses at rated power 393 W
Long term stability for 1000 hours (of output voltage) 0.15%
Charger characteristic per IEC 47810: IU
High voltage insulation between input/output and electrical earth 2500V AC
(With disconnected electronic boards in the rectifier).
Insulation resistance with disconnected electronic boards in the
Rectifier >200MΩ
Input to ground 500V DC
Input to output 500V DC
Output to ground 500V DC
Protection:
• Slow start function
• Short circuits
• Limited at 100% of rated current
• Internal DC fuse
• Nonvolatile storage of system parameters and user settings
• Mains failure shutdown, Rectifier failure shutdown
• High voltage DC shutdown
• History function for time stamped alarm and system events
Battery adjustments
(If battery is included in scope of supply, it must appear as a separate line in the quote)
Manufacturer Enersys
Type HX
Capacity 47 Ah
Number of cells 0
Number of strings 1
Float charge voltage 0,00 V
High rate voltage 0,00 V
High rate charge time (range 0150h): 4 h
High rate charge timer mode settings Post
Commissioning voltage 0,00 V
End of discharge voltage 0,00 V
Measurements – Alarms
Measurements available on LCD display:
• AC input voltage
• DC charger voltage
• DC charger current
• DC battery current
• Battery capacity
• DC load voltage
• DC load current
Alarm indications:
• Mains voltage alarm
• Charge fault alarm
• Battery voltage alarm
• DC voltage alarm
• Ground fault +/alarm
• Charger current limit alarm
• Battery current limit alarm
• High charger current alarm
• High battery current alarm
• high temperature alarm
• Temperature sensor error alarm
• Internal communication error alarm
• Battery test alarm
• High battery temperature alarm
• Long charge time alarm
• No power supply voltage alarm
• Battery in operation alarm
• Service alarms
List of installed items
• EMI filter (CE)
• Voltage temperature compensation (cable length 30m)
• Bridge temperature alarm
• AC input protection: Switch
• Battery protection: Fuse
• Load protection: None
• Ground fault (by With GCAU)
• Cabinet colour: RAL7035
• Cabinet protection degree: IP21
Orijinal Ürün
Hızlı Kargo
7/24 Destek
Tedersan olarak, AEG markasının 24SPRE50 ürününü global tedarik ağımız üzerinden temin ediyoruz. Bu ürün, endüstriyel uygulamalarınızda yüksek performans ve güvenilirlik sağlamak üzere tasarlanmıştır.
Ürün Özellikleri
• Orijinal AEG ürünü
• Fabrika garantili
• Hızlı teslimat (Talebe Göre Değişmektedir)
• Teknik destek
Tedarik Süreci
Tedersan, 24SPRE50 ürününü global tedarikçi ağımız üzerinden temin ederek size ulaştırıyoruz. Ürün taleplerinize en geç 2 iş günü içerisinde fiyat teklifi sunuyoruz.
Neden Tedersan?
• 10+ yıllık tecrübe
• Geniş ürün yelpazesi
• Rekabetçi fiyatlar
• Güvenilir teslimat